Library

10.9.7 Temporary Signage

Maintenance, commissioning, antenna replacement, temporary transmitters, emergency repairs, and changing operating modes may temporarily alter RF boundaries or entry conditions.

Portable signs, barriers, and notices should identify the temporary boundary, the applicable source state, the required controls, and an appropriate contact. They should be removed or updated when the temporary arrangement ends so that obsolete instructions do not remain.

10.9.8 Sign Design

RF safety signs should comply with the occupational safety-sign requirements applicable in the jurisdiction. In Australia, RPS S-1 refers to AS 1319 for signs or notices used in the protection of the public.

Effective signs are:

Wording should be concise and state the required action. Detailed procedures are better provided in a permit, site instruction, or other controlled document referenced by the sign.

10.9.9 Inspection And Maintenance

Signs and markings are controls and must be inspected and maintained. Routine inspection should verify that:

The signage and markings should be reviewed whenever transmitter power, frequency, antenna configuration, operating modes, source ownership, access arrangements, or the exposure assessment changes.