Library

10.10.8 Working At Shared Sites

Shared towers, rooftops, antenna farms, and equipment rooms may contain sources owned or controlled by several organizations. The site owner, source operators, contractors, and Responsible Person must consult, cooperate, and coordinate so that all sources affecting the work are managed.

Before work begins, they should confirm:

No source should be restored, reconfigured, or tested in a way that affects the work area until the agreed release has been received from every protected work group.

10.10.9 Completion Of Work

The safe system of work continues through completion, handback, and restoration. Before a source is returned to service:

If the work changed antenna characteristics, transmitter power, frequency, operating modes, shielding, access, or the surrounding environment, the exposure assessment and applicable Plan should be reviewed before unrestricted operation resumes.