Library

10.10.6 Verification Before Entry

A source should not be assumed safe merely because a shutdown or isolation instruction has been issued.

Before access, an authorized person should verify that the specified controls and source states are in place and that no overlooked source can affect the work area.

Verification may include:

The required method should be specified in the procedure. Verification is particularly important at shared sites, with software-controlled or intermittent sources, and where several transmitters can affect the same area.

10.10.7 Working Near Energized Equipment

Some testing, fault finding, commissioning, and operational tasks may require work near energized RF sources. Such work should proceed only under a documented assessment and authorized procedure that keeps exposure within the applicable limits.

The reason energized work is necessary, the assessed exposure, the permitted source states, the controls, and the stop-work criteria should be documented. A personal RF monitor or time limit must not be used to justify otherwise noncompliant work.