3.1.9 Verifying Functionality Of Flowing Out Module
Like the Flowing In module, the Flowing Out module must also verified to determine that it performs to the requirements specified. To avoid drawing water from BATHTUB when stock of water becomes zero, the module is modified. Modification involves stopping Flowing Out and pausing the simulation at, say, 0.01 litres, just before BATHTUB becomes completely empty. Functional details are provided in Table 3-5 and Figure 3-35.
Table 3-5. Additional Functionality Defined for Flowing Out Module
Variable Name | Functional Definition |
|---|---|
Flowing Out | (30*1<<l/min>>) *IF(BATHTUB<=0.01<<l>>,0,1) |
Pause When Empty | PAUSEIF(BATHTUB<=0.01<<l>>) |